EducationTechnical Info

Unintended Consequences

Posts Tagged ‘System design’

Unintended Consequences

Monday, January 11th, 2010

Energy conservation is a very interesting field.  With the advances of technology we have items like solar panels for energy generation or water heating, battery technology for energy storage and new forms of lighting like LED lamps.  A recent article on LED lamps caught my attention recently and I thought it would be a good example for comparison to ammonia refrigeration systems.

(more…)

Ammonia Refrigeration Installations

Friday, December 18th, 2009

Ammonia refrigeration systems are complex by their very nature.  A system can be comprised of a mixture of various manufacturers equipment such as evaporators, compressors, control valves, condensers, and vessels.  Secondly, you can have various forms of each of these components.  Screws or reciprocating compressors.  Evaporative or shell & tube condensers.  Flooded, direct expansion, or liquid overfeed coil circuiting.
(more…)

Heat Recovery Methods

Sunday, November 1st, 2009

I often see people interested in heat recovery asking questions about desuperheating.  This mode of heat recovery is based on circulating a fluid such as water through a heat exchanger to aid in transferring heat from one location to another.  One of the major issues with utilizing the superheat of the discharge gas from a refrigeration systems is; there is not a lot of available heat!  The available superheat in the discharge gas from a compressor is only a small percentage of the the total available heat energy.

(more…)

Industrial Heat Pumps

Monday, October 26th, 2009

I usually observe the surroundings and watch for the color change of the trees during this time of the year.  As I was driving back from a project this last week I happened to notice something I thought was slightly ironic.  At one bend in the highway there were patches of steam over the horizon.  These are certainly more visible during this time of year with cooler ambient weather conditions.  As I drove closer to the facility the source of the steam became apparent.

(more…)

Hand Expansion Valves - 4

Thursday, October 22nd, 2009

In the final entry on this series, the application of hand expansion valves (HEV) to liquid overfeed systems will be discussed.  The application of HEV’s in this type of system somewhat differs from those of the prior discussions.  When selecting HEV’s for the evaporators where liquid overfeed is being utilized the hand expansion valves take on a secondary function, which may not be obvious at first glance.

(more…)

Hand Expansion Valves - 3

Monday, October 19th, 2009

In this entry a unique application for hand expansion valves (HEV) is discussed.  Many vessels in industrial refrigeration systems have what we call “float columns”.   These float columns usually have mechanical float switches which actuate on predetermined liquid levels within the vessel.  It is also common to find capacitance type level probes installed in the float columns to monitor liquid level in the attached vessel.

(more…)

Hand Expansion Valves - 2

Sunday, October 18th, 2009

In the previous blog entry we discussed the use of hand expansion valves (HEV) maintaining a liquid level in a vessel.  In this entry the discussion will center on the HEV being utilized as an expansion device to an evaporator being fed with liquid from a controlled-pressure receiver (CPR).

(more…)